Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller

Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller
Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller
Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller
Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller
Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller
Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller
Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller
Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller
Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller
Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller

Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller
Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controllers. 1 x Nexsan E18 2U Storage Array with.

18 x 3.5 SAS Drive Bays (No Caddies Included). 2 x Host Controllers P3500465 with.

Simultaneous Fibre Channel and iSCSI: Yes. 1Gb iSCSI Ports per Controller: 2. 8Gb FC Ports per Controller: 2. 12Gb/s SAS Ports per Controller: 2.

10/100/1000 MbE Management Ports: 1 per Controller. 2 x 8Gb SFP Transceiver Modules. 2 x 1000W Power Supplies. Nexsan E18 SAN RAID Array. The Nexsan E18 is a block-level RAID disk array that fits 18 disks in 2U of rackspace, for up to 10.8TB of storage capacity per unit. Completely OS-independent, these disk arrays offer dual-function Fibre Channel and iSCSI host connectivity with wire-speed throughput. Configurations can feature single or dual RAID controllers, and each RAID controller features 2GB of battery-backed DDR3 cache and dual RAID engines. Nexsan E18 connectivity is provided via 2 x 8Gbps Fibre Channels ports and dual 1Gbps iSCSI supports.

The ports can be used simultaneously to support multiple workloads on a single array. The Nexsan E18 disk array can also support multiple RAID sets with multiple volumes per set, and up to 254 LUNs. To maximize the reliability and ease-of-use of this disk expansion unit, the Nexsan E18 features a design layout of the disk drives being located in 2 self-contained disk drawers. Each drawer contains 9 disk bays, and tachometer -controlled push and pull fan modules.

Other features of this unique design include. Each drawer can have a different drive type of SAS or SSD.

Use any supported Nexsan RAID type (RAID 0, 1, 1+0, 4, 5 and 6). Create multiple RAID sets within a single drawer. Create a RAID set across two or three drawers. Nexsan's specially-designed cables for this disk expansion unit enables drawers to be pulled out so service can be performed to disks and fan within the unit without affecting operation or availability.

The design of the Nexsan E18 expansion unit includes many of the reliability features included with their other disk arrays. Redundant, individually hot-swappable disks, expansion interface modules, and fans. Anti-Accumulative Rotational vibration design maximizes disk reliability. Horizontal mid-plane maximizes cooling for optimal operating conditions. RAID sets can be automatically rebuilt with hot spares.

Multi-path architecture to eliminate single points-of-failure. Nexsan's patented MAID (Massive Array of Idle Disks) technology, AutoMAID, is designed to provide real cost savings by reducing the energy requirements & thermal output of unused drives. This feature comes standard on all of Nexsan's E18 disk arrays, and provides transparent cost savings without requiring any software changes. AutoMAID allows IT to choose what combination of cost savings and performance requirements fits their business needs, with four levels of "idleness". Level 1: at this level, disks can achieve 15% - 20% savings by unloading the head. The disks keep spinning though, providing sub-second recovery times. Level 2: achieve 35% - 45% savings by unloading the heads and slowing the disk down to 4000 RPM. At this level, recovery times average 15 seconds.

Level 3: further increase powersavings by stopping the disk spin and putting it into sleep mode, but powered on. This level provides 60% - 75% savings, and 30-45 second recovery times. Level 4: maximize power savings by approximately 87% by powering the drive off, while still featuring 45-60 second recovery times to initial I/O requests. Data is continuously verified with Nexsan's AutoMAID technology, which performs periodic surface scans to ensure data integrity. Host fibre connection : 2 x Dual 8Gbit fibre ports.

Host iSCSI connection : 2 x Dual 1Gbit iSCSI ports. Tuesday 26-Jul-2022 10:55:18. (C0): 0Days 00:16:58.

(C1): 0Days 00:17:06. There are no problems with this system. 12V Rail 12.42 (12.41 - 12.43)V : OK. 12V Rail 12.36 (12.36 - 12.37)V : OK. Front: Fan0 RPM: 2542 : OK.

Rear : Fan0 RPM: 2990 : OK. 12V Rail 12.12 (12.12 - 12.12)V : OK. Front: Fan0 RPM: 2398 : OK. Rear : Fan0 RPM: 2626 : OK.

(C0): 1.18 1.18. (C1): 1.18 1.18. (C0): 0.97 0.97. (C1): 0.97 0.97. (C0): 1.06 1.06. (C1): 1.06 1.06. (C0): 1.79 1.79. (C1): 1.79 1.79. (C0): 2.51 2.51. (C1): 2.51 2.51. (C0): 3.31 3.31. (C1): 3.31 3.31.

(C0): 5.10 5.07. (C1): 5.10 5.07. (C0):12.12 (12.12 - 12.12)V : OK. (C1):12.12 (12.12 - 12.12)V : OK.

Unused / Pool Spare Disks. Power level 2 : 10 mins. Critical Hours: 00:15 - 508:00 Fri Sun. Collecting AutoMAID statistics - please try again later. Reporting period from Tuesday 26-Jul-2022 10:38 to Tuesday 26-Jul-2022 10:55.

There are no volumes configured. Loop state: (H0): Link Down. (H0): AVAGO, 8G, AA1317A1GKT, LC.

(H1): AVAGO, 8G, AA1319A24DK, LC. (H0): AVAGO, 8G, AA1319A23D6, LC. (H1): FINISAR, 8G, PQA2AFR, LC. There are no encryption keys installed.

Link Status (Mgt): Link Up. (Mgt): 10.10.10.9. Subnet mask (Mgt): 255.255.255.0. (Mgt): 10.10.10.1. Primary DNS (Mgt): Not configured. Link Status (Mgt): Link Down. (Mgt): Auto Spd, Auto Duplex (N0): Auto Spd, Auto Duplex (N1): Auto Spd, Auto Duplex. Port Status (Mgt): 100Mbit Full Duplex. Port Status (Mgt): Link Down. DHCP/DNS Update (Mgt): N/A (Link Down). 129.6.15.28 (from static list). Retrieved time server data : No data retrieved. GUI ADMIN login password : Configured, Account Enabled. FriendlyName Model (SysID) AlertType Event. Send Traps to IP address. Send Traps to IP address 2 : Not configured. When To Send SNMP Traps.

VAT IS NOT PAYABLE BY PURCHASERS OUTSIDE OF THE UK. This item is in the category "Computers/Tablets & Networking\Enterprise Networking, Servers\Network Storage Disk Arrays\SAN Disk Arrays". The seller is "itinstock" and is located in this country: GB.

This item can be shipped worldwide.


Nexsan E18 Storage Array 18x 3.5 Bay 2x Dual Port 8Gb FC / 1Gb iSCSI Controller


Home  Archives  Contact  Privacy Policies  Terms of Use